CHAPTER51 Reporting Information to External Party
Mediant 4000 SBC | User's Manual
Field Description
■ The default field title is "%" for Syslog.
■ The maximum number of characters for Syslog tabular alignment is 3.
AMD
Decision
[629]
Displays the detected answering type for the AMD feature:
■ "V": voice
■ "A": answer machine
■ "S": silence
■ "U": unknown
Note:
■ The field is included in the default CDR.
■ The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
■ The field is applicable only to SBC media and Gateway CDRs.
■ The default field title is "AMD" for Syslog.
■ The maximum number of characters for Syslog tabular alignment is 3.
Blank
[308]
Displays an empty string value " " and 0 for an integer value. This is typically
used for RADIUS CDRs.
Note:
■ The field is optional and can be included in the CDR using the SBC CDR
Format and Gateway CDR Format tables.
■ The field is applicable to all CDR Report Types.
■ The maximum number of characters for Syslog tabular alignment is 5.
Call
Duration
[408]
Displays the duration of the call. The field is an integer.
Note:
■ To configure the units of measurement (seconds - default, deciseconds,
centiseconds, or milliseconds), use the [CallDurationUnits] parameter.
■ The field is included in the default CDR.
■ The field is applicable only to "CALL_END" CDR Report Types.
■ The field is applicable only to SBC signaling and Gateway CDRs.
■ The default field title is "Duration" for Syslog and Local Storage, and none
for RADIUS (ACCT_SESSION_TIME standard ID 46).
■ The maximum number of characters for Syslog tabular alignment is 8.
Call End
Sequence
Number
[442]
Displays the sequence number of the call. The field is an integer. For each call-
end CDR, the field is assigned the next consecutive number. For example, for
the first terminated call processed by the device, the field is assigned the value
"1"; for the second terminated call, the field is assigned the value "2", and so
on. The field value resets to 1 upon a device reset, an HA switchover (for HA-
supporting products), or when it reaches the value FFFFFFFF (hexadecimal).
As the field is consecutive, you can use this field to check whether there are
any missing CDRs.
Note:
■ The field is optional and can be included in the CDR using the SBC CDR
Format and Gateway CDR Format tables.
■ The field is applicable only to "CALL_END" CDR Report Types.
- 771 -