EasyManua.ls Logo

AudioCodes Mediant 4000 SBC - Page 821

AudioCodes Mediant 4000 SBC
1037 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER51 Reporting Information to External Party
Mediant 4000 SBC | User's Manual
Field Description
"DIALOG_CONNECT ": The CDR is sent upon establishment of a non-
INVITE session (only when enabled, using the EnableNonCallCdr
parameter).
"MEDIA_START": The CDR is sent upon 200 OK response or early media
"MEDIA_UPDATE": The CDR is sent upon a re-INVITE message
"MEDIA_END": The CDR sent is upon a BYE message
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable to SBC media and signaling, and Gateway CDRs.
The default field title is "GWReportType" for Gateway Syslog and Local
Storage, "SBCReportType" for SBC Syslog and Local Storage, and
"MediaReportType" for SBC Syslog Media.
The maximum number of characters for Syslog tabular alignment is 15.
RTP IP
DiffServ
[624]
The field displays the RTP IP DiffServ. The valid value is an integer from 0 to
63.
Note:
The field is included in the default CDR.
The field is applicable to "CALL_END", "CALL_CONNECT", "MEDIA_
START", "MEDIA_UPDATE", "MEDIA_END" CDR Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "TxRTPIPDiffServ".
The maximum number of characters for Syslog tabular alignment is 15.
Session ID
[302]
Displays the unique session ID. The field value is a string of up to 24
characters.
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable to SBC media and signaling, and Gateway CDRs.
The default field title is "SessionId".
The maximum number of characters for Syslog tabular alignment is 24.
Setup Time
[411]
Displays the date and time that the call was setup. The field value is a string of
up to 35 characters and presented in the following format:
<hh:mm:ss:ms> UTC <DDD> <MMM> <DD> <YYYY>. For example,
"17:00:49.052 UTC Thu Dec 14 2017"
Note:
To configure the time zone string (e.g., "UTC" - default, "GMT+1", and
"EST"), use the TimeZoneFormat parameter.
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The default field title is "SetupTime"" for Syslog and Local Storage, and
"h323-setup-time=" for RADIUS.
- 788 -

Table of Contents

Other manuals for AudioCodes Mediant 4000 SBC

Related product manuals