CHAPTER51 Reporting Information to External Party
Mediant 4000 SBC | User's Manual
Attrib-
ute ID
Attribute
Name
Vendor-
Specific
Attribute
(VSA) ID
Description
Value
Format
Example AAA
40 acct-
status-
type
(Standar
d)
Account
Request Type
- start (1) or
stop (2)
Note: ‘start’
isn’t
supported on
the Calling
Card
application.
Numeri
c
1 Star
t
Acc
Stop
Acc
41 acct-delay-
time
(Standar
d)
No. of
seconds tried
in sending a
particular
record
Numeri
c
5 Star
t
Acc
Stop
Acc
42 acct-input-
octets
(Standar
d)
Number of
octets
received for
that call
duration
(applicable
only if media
anchoring)
Numeri
c
- Stop
Acc
43 acct-
output-
octets
(Standar
d)
Number of
octets sent
for that call
duration
(applicable
only if media
anchoring)
Numeri
c
- Stop
Acc
44 acct-
session-id
(Standar
d)
A unique
accounting
identifier -
match start &
stop
String 34832 Star
t
Acc
Stop
Acc
46 acct-
session-
time
(Standar
d)
For how many
seconds the
user received
the service
Numeri
c
- Stop
Acc
47 acct-input-
packets
(Standar
d)
Number of
packets
received
during the call
Numeri
c
- Stop
Acc
- 809 -