CHAPTER3 SNMP Trap Events (Notifications)
MSBR | SNMP Alarms
Event acProxyConnectivity
the proxy is
available
again
now IN SERVICE"
Cold Start Trap
Table 3-13: coldStart
Event ColdStart
OID 1.3.6.1.6.3.1.1.5.1
MIB SNMPv2-MIB
Description The alarm is sent if the device reinitializes following, for example, a power
failure, crash, or CLI reload command. Categorized by the RFC as a
“generic trap”.
Note This is a trap from the standard SNMP MIB.
Authentication Failure Trap
Table 3-14: authenticationFailure
Event authenticationFailure
OID 1.3.6.1.6.3.1.1.5.5
MIB SNMPv2-MIB
Description The trap is sent if the SNMPv2 entity, acting in an agent role, has received
a protocol message that is not properly authenticated. While all
implementations of the SNMPv2 must be capable of generating this trap,
the snmpEnableAuthenTraps object indicates whether this trap will be
generated.
Note: You can disable the sending of this SNMP trap, using the
[EnableSnmpAuthenticationTrap] parameter.
Board Initialization Completed Trap
This is the AudioCodes Enterprise application cold start trap.
- 73 -