CHAPTER3 SNMP Trap Events (Notifications)
MSBR | SNMP Alarms
Table 3-15: acBoardEvBoardStarted
Event acBoardEvBoardStarted
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.4
Description The alarm is sent after the device is successfully restored and initialized
following reset.
MIB AcBoard
Severity cleared
Event Type equipmentAlarm
Probable
Cause
Other(0)
Alarm Text Initialization Ended
Configuration Change Trap
Table 3-16: entConfigChange
Event entConfigChange
OID 1.3.6.1.2.1.4.7.2
MIB ENTITY-MIB
Description The alarm is sent if a change in the device's hardware is detected, for
example, when a module is removed from the chassis.
Link Up Trap
Table 3-17: linkUp
Event linkUp
OID 1.3.6.1.6.3.1.1.5.4
MIB IF-MIB
Description The alarm is sent if the operational status of a communication link (e.g.,
an Ethernet port interface) changes from “down”. Categorized by the RFC
as an “enterprise-specific trap”.
By default, the index of the interface is included in the trap. If you want to
disable the inclusion of the index, configure the
- 74 -