AUX air conditioner service manual
Outdoor unitDouble pole AC. Contractor wiring diagram
Ye l lo w /G re en
Black
Red
For series o f 240 00 Bt u/h
Ou t do or U ni t
Electric Chart
To Indoor Unit
To Indoor
Unit
Fan Motor
Compressor
Col d Wind Type
Compressor
Ov er curr ent
Protector
Ca pacit or
Co m pr e s s o r
Black
Br ow n
Ye l l o w
(R)
(B)
1
2
Y/G
Black
Brown
Contact
Fa n motor
Capa citor
White
Re d
Black
Red
Com press o r
Capa citor
Heat-Pump Type
For ser ies o f 24000 Btu/h
Outdoor Unit
Electric Chart
To Indoor
Unit
Brown
(BR)
Yell ow
Bla ck
To I ndoor Unit
Red
Green
Blue
(B)
21
(R)
Y/G
(B L)
54
To Indoor
Unit
Compress or
Fan Motor
Fan Motor
Compressor
Contact
Black
Brown
Yellow
Overc urrent
Pro tec t or
White
Red
Capacitor
Black
Brown
Black
Blue
Yell ow
Blue
Gr e e n
Red
Orientation
Valv e
Sens or
Te mp er atu re
175