AUX air conditioner service manual
16
air-conditioner. Although the unit “W” is same as the one used for the cooling capacity, they have
different practice signification: As we all know 1Hp=735.499W, which stands for the consumption
power of the compressor, but the cooling capacity indicates the quantity of heat absorbed from the
room by air-conditioner within a unit time. So, somebody may ask: is this against the energy
conversation law? The answer is: we shall consider about the energy conversation law in a total
air-conditioning system: e.g. the power consumption of the compressor (+other power consumption by
fan and motor etc.) + the quantity of heat (e.g. the cooling capacity) absorbed from the room=the
ejecting quantity of heat by the (Outdoor part) air-conditioner.
The general units’ conversion is as follows:
1Hp (or 1 Horse Power) =735.499W the abbreviation is 735W (British unit Horse Power=745.7W)
1W=0.86kcal/h(Kcal. or Therm)
1kcal/h=3.9683Btu in abbreviation of 4Btu
1W=3.412Btu/h
1cooling ton=13878kJ/h=3330kcal/h=3873W (US cooling ton and Japanese cooling ton)
t Celsius degree ()=T absolute temperature (K)-273.16
t Fahrenheit ()=9/5t+32()
1Pa=1.02*10-5kgf/cm²
The noise of air-conditioner:
It’s not allowed to have the strange noise and vibration when the air-conditioner is running. The
regulations with regard to this issue are specified as following:
The error is permitted by the manufacturer if +3dB(A) in difference with the announced figure (by
nameplate, manual or adv. Etc.) of the air-conditioners noise.
T1T2 model air-conditioner shall be tested in the Semi-anechoic Room, There are 2dB(A) can be
added to T3, Sound Pressure Level.
The noise value obtained from the anechoic room must be noted by the letters of “Tested in the
overall noise eliminated room”.
The difference between the noise level + interference and the rating noise value shall not less than
10dB (A) when the noise test ongoing.
The ground shall be the reflection surface when there is semi-noise eliminated, and the noise space
is consisting of 2 indoor and outdoor rooms.
The measurement to the noise shall be undertaken 30 minutes later after the air-conditioner running
normally and when the ambiance temperature reach ±1.5 of the rating working status.
The measurement shall be undertaken at the point of 1meter height and 1 meter far away to the
front panel of the air-conditioner.