EasyManuals Logo

AUX E Series User Manual

AUX E Series
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #238 background imageLoading...
Page #238 background image
AUX air conditioner service manual
235
4. Heat Conductivity Factors of Several Common Used Material
Material
λkJ/m·h·
Material
λkJ/m·h·
Copper 1382 Cork 0.17-0.25
Aluminum 733 Air Interlayer 0.25
Steel 163 Water 2.1
Frosty layer 2.1 Glass 2.7-2.9
Fibre Glass 0.17-0.21 Saw Timber 0.25-0.34
Glass Cloth 0.13 Plywood 0.62-0.84
Slag Wool 0.21-0.34 Polyurethane Foam 0.042-0.11
5. Basic Property of Substitute Refrigerant
Property R-22 R-410A R-407C
R-22 R32/R125
R32/R125/
R134a
Refrigerant Composition
Mass Ratio %)
100 50/50 23/25/52
ODP 0.05 0 0 Environme
nt
Protection
GWP100Y
1730 1700 1530
Toxicity None None None
Safety
Combustibility Incombustible Incombustible Incombustible
Azeotropic Prop --- Subazeotropic Subazeotropic
Boil Temp
-40.8 -52.7 -43.7
Thermo-ph
ysical
Properties
Critical Temp
96.1 72.5 87.3
Refrigeration
PressureMpa
2.17 3.38 2.31
Evaporation
PressureMpa
0.62 1.00 0.64
Pressure Ratio 3.50 3.38 3.59
Exhaust Temp
97.2 95.1 86.7
Refrigerati
on
Properties
Slip Temp
0
0.17 以下 46

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX E Series and is the answer not in the manual?

AUX E Series Specifications

General IconGeneral
BrandAUX
ModelE Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals