EasyManuals Logo

AUX E Series User Manual

AUX E Series
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
AUX air conditioner service manual
Self-detection sequence chart
b) Time-Lapse function
The air-conditioner starts the time-Lapse function after the self-detection and the starts with electricity.
Any operation processes in need of time extension or counting can be carried out along with the
time-lapse process (including timing on/off, sleeping, system protection, time delay etc.); the remote
signal and button signal is receivable during the time-lapse function. It needs to be re-electrified before
quit.
Auto-restart/memory functionthe basis models have no such additional function
Being re-electrified after electricity being cut off, and the following conditions are going to
be memorizedmode, fan speed, setting temperature, swing status, on-off status. If it’s under
operation status before electricity being cut off, there is three minutes delay protection
function after being re-electrified and start. If it’s under close status before electricity being
cut off, there is no three minutes delay protection function after being re-electrified and start.
The primarily electrifying process defaults the auto-restart memory function.
Faults display
When the fault happenthe LCD numerical panel displays the corresponding code of the fault.
a)Fault of the indoor room temperature sensor
System stops, the LCD numerical panel displays E1.
b) Fault of the indoor coil temperature sensor
System stops, the LCD numerical panel displays E3.
87

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX E Series and is the answer not in the manual?

AUX E Series Specifications

General IconGeneral
BrandAUX
ModelE Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals