AUX air conditioner service manual
38
the temperature difference correction value shall be -1℃,if the wind speed of the indoor fan rises by
one gear, the temperature difference correction value shall be +1.
a)The accumulated operation time of the compressor3hour
b)The continuous operation time of the compressor20 minutes
c) The difference value between TE and TA less than Y.
aThe difference value between TE and TA less than Y and continuously last for 5minutes
b)The accumulated operation time of the compressor is over than 45minutes
c)The continuous operation time of the compressor is over than 20minutes
The air-conditioner starts the defrosting process if satisfying the conditions, and records the TE value
then before defrosting starts. Compare the TE value after defrosting with the one before defrosting, if
the value of the later is not 3 more than the former one, it will not start the defrosting process
according to this condition until the mode conversed and the air-conditioner to be restarted for heating
or after another defrosting process;
The air-conditioner starts time counting after overheating protection delay (the outdoor fan stops)
and starts an force defrosting process two hours later.
The intelligent defrosting process quit if satisfying one of the below four conditions:
a)The duration of the intelligent defrosting process9min
b)After the 4 minutes defrosting processif TE0 and the TE rise by 2 within 10seconds
c)After the 5 minutes defrosting processif TE5℃;
d)Test the current of the compressor 1 minute later after compressor starts, When the current of the
compressor 6A3.2Kw3.5Kw wall-mounted unit require the current of the compressor8Aand
continuous lasts for 5 seconds.
The sleeping control function
The sleeping control function is valid during the automatic, cooling, dehumidifying and heating
mode. The wind speed of the indoor fan falls by one gear after starts the sleeping control function and
the sleeping indication lamp on;
Press the button of “sleeping” and start the sleeping process. The default temperature rises by 1 to
the ongoing cooling mode after 1 hour running; the default temperature falls by 2 to the ongoing
heating mode after 1 hour running; after another 1 hour running, the default temperature for the
ongoing cooling process rises by 1 and falls by 2 for the ongoing heating process. The sleeping
process last for 7 hours until power-off.
The modes switch function is still valid after enter into the sleeping process, but will quit after
modes switched. The air-conditioner runs at the temperature value of “new default temperature +
correction temperature” if press the button of temperature “+”.
Under the sleeping status, press the button of “sleeping” again or press the modes option and on-off
button to quit sleeping function and end the sleeping process.