EasyManuals Logo

AUX E Series User Manual

AUX E Series
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
AUX air conditioner service manual
heating quit during the operation process of the compressor.
Sleeping control function
The sleeping function is valid during the automatic, cooling, dehumidifying and heating process. The
indoor fan runs at low fan speed during sleeping mode, and the sleeping indication light on;
After turning into the sleeping process by pressing down the button of “sleeping” on the remote
controller, to the Cooling process, the setting temperature rises by 1 automatically one hour later; to
the Heating process, the setting temperature falls by 2 automatically one hour later. After another 1
hour, the setting temperature of the Cooling process raises another 1, and the one of the Heating
process falls another 2. The sleeping process lasts 7 hours until air-conditioner turns off.
During the sleeping process, the mode switching operation is allowed and workable, but it will delete
the sleeping function. The air-conditioner will run at the temperature of “new setting temperature +
temperature correction” if press the button of add temp.“+”.Under the sleeping status, if press down
the button of “sleeping” or change modes or on-off, the sleeping process will be deleted and ended.
The sleeping process under cooling mode:
Setting temperature
rises another 1
rises 1
50
Previous Setting
temperature
1h 2h 7hend sleeping processturn off
The sleeping process under heating mode:
Setting temperature
Previous setting falls 2
temperature
Falls another 2
1h 2h 7hend sleeping processturn off
Timing control function
The time range of the Timing control set is 24 hours, and the time unit is minute, single
timing mode. The conversion of the modes doesn’t cancel the timing function, and the timing
indication light turns on after timing setting.
Timing turns off
The timing turns off function can be set only under the running status of the air-conditioner. The

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX E Series and is the answer not in the manual?

AUX E Series Specifications

General IconGeneral
BrandAUX
ModelE Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals