AUX air conditioner service manual
226
The “running” light and “swing” light are twinkling and last for 0.5/0.5 second, the other indication
lights are invariable, and the system turns off.
4. ASF-H24B4/B, ASF-H41A5/B faults display and protection display:
⑴ Fault of the Indoor temperature sensor:
System turns off; the panel displays “E1”
⑵ The fault of the outdoor tube temperature sensor on the indoor panel:
System doesn’t turn off; the panel displays“E2”.
⑶ Fault of the interior tube temperature sensor:
System doesn’t turn off, the panel display “E3”,runs under the mode without interior temperature
sensor:When under the heating mode, there is no overheating protection, anti-cooling wind protection
and residual heat removal function, the indoor fan starts running at the setting fan speed 30 seconds
later after the compressor’s starting, and stops after 30 seconds running at the ultra low fan speed
without compressor; When under the refrigeration mode, there is no anti-freezing protection.
⑷ Communication fault:
The system turns off or can’t start, the panel displays “E4”,which may be displayed under either on or
off status.
⑸ The protection of outdoor reverse phase and failure of phase:
System stops, and the panel displays “E6”
⑹Heating and defrosting:
The “defrosting” indication light on the panel is twinkling, (0.5/0.5) the other are invariable.
⑺ When the indoor tube temperature available, the indoor refrigeration anti-freezing protection:
The “running” light and “cooling” light on the panel are twinkling (0.5/0.5), the other are invariable.
⑻ When the indoor tube temperature available, the indoor heating overheating protection:
The “running” light and “heating” light on the panel are twinkling (0.5/0.5), the other are invariable.
⑼ When the indoor tube temperature available, the indoor heating long time anti-cooling wind
protection:
The “running” light on the panel is twinkling (0.5/0.5), the other are invariable.
5、ASW-(H)18A4/III fault display and protection display
⑴ Damage to the outdoor coil pipe:
The timing light on the panel twinkles one time/second.
⑵ The damage to the indoor temperature sensor:
The timing light on the panel twinkles one time/8 seconds.
⑶ The damage to the indoor coil pipe sensor:
The timing light on the panel twinkles two times/8 seconds.
⑷ Heating and defrosting
The sleeping light twinkles (0.5/0.5 second)
⑸ Refrigerating anti-freezing protection:
The operation light and the timing light of the panel twinkle (0.5/0.5 second)
6、Heating anti-overheating protection:
The “running” light and “sleeping” light are twinkling(0.5/0.5second)
⑺ Heating long time anti-cooling wind protection:
The “running” light is twinkling(0.5/0.5second)
6、FS(Y)、DS(Y) 、ZVY、CSY model air-conditioner faults display and protection display