AUX air conditioner service manual
225
short circuit.
Fault 24 No load.
Fault 26 Outdoor over-current protection.
Fault 28 Outdoor voltage abnormal.
Fault 29 Outdoor electric source’s instant off.
Fault 2A Outdoor refrigeration’s overloading protection.
Fault2B Outdoor defrosting display.
Fault 2C IPM module fault.
Fault 2d Outdoor E2 data fault.
Simultaneously press the key of “hour”, “minute” again and last for 2 seconds. Resume displaying the
temperature after the sound of the buzzer.
3ASF-H24B4/A,ASF-H41A5/A,ASF-H41A5/C faults display and protections display
Heating and defrosting
The “heating” indication light on the panel is twinkling, 0.5/0.5the others are invariable.
When the indoor tube temperature available, the indoor refrigeration anti-freezing protection
The “running” and the “cooling” indication light on the panel is twinkling0.5/0.5the others are
invariable.
When the indoor tube temperature available, the indoor heating over-heating protection
The “running” and the “heating” indication light on the panel is twinkling0.5/0.5the others are
invariable.
When the indoor tube temperature available, the indoor heating long time anti-cooling wind
protection
The “running” indication light on the panel is twinkling0.5/0.5the others are invariable.
Over-current protection:
The “running” light and “29” indication light on the panel are twinkling and simultaneously last for
0.5/0.5 second, the system turns off.
6Low pressure protection
The “running” light and “18” indication light on the panel are twinkling and simultaneously last for
0.5/0.5 second, the system turns off.
Fault of the indoor temperature sensor
The “temperature” indication light on the panel is twinkling and last for 0.5/0.5 second, the system
turns off.
Fault of the indoor coil pipe sensor
The “temperature” indication light on the panel is twinkling and last for 0.5/0.5 second, runs without
the interior tube sensor.
The outdoor coil pipe sensor and the compressor discharge sensor fault
The “running” indication light on the panel is twinkling and last for 0.5/0.5 secondthe others are
invariable.
Outdoor failure of phase or the phases sequence protection:
The “timing” light and “running” light on the panel are twinkling and simultaneously last for 0.5/0.5
second, the system turns off.
fault of Communication:
The “running” light on the panel is twinkling and last for 0.5/0.5 second, the other indication lights are
off, and the system turns off.
Compressor discharge protection: