AUX air conditioner service manual
89
Air blade type
Centrifugal
blade
Centrifugal
blade
Centrifugal
blade
Centrifugal
blade
Specification of
air blade
(dia.-length
mm)
350-152 350-152 350-152 350-152
Model of the
step-motor
49TDY/49TD
J
49TDY/49TDJ
49TDY/49TD
J
49TDY/49TDJ
Power W 3 3 3 3
Fuse A 3.5 3.5 3.5 3.5
Noise dB(A) 38~42 38~42 41~48 42~49
Dimension cm
(L×W×H)
30×48.3×170.
5
30×48.3×170.5
30×48.3×170.
5
30×48.3×170.5
Net weight (kg) 36 36 36 38
Specification of
the electric
cable
3×2.5mm
2
3×2.5mm
2
3×3.0mm
2
3×3.0mm
2
Specification of
the electric
connecting
cable
3×1.5mm
2
2×0.75mm
2
3×1.5mm
2
2×0.75mm
2
3×2.5mm
2
3×0.75mm
2
3×2.5mm
2
3×0.75mm
2
Total unit
ASF-H18A4
/
CZ(ZZ)
ASF-H18B4/
CZ(ZZP)
ASF-H24A4/
CZ(ZZP)
ASF-H24B4/
CZ(ZZP)
Indoor unit
ASF-H18A4
/C(Z)
ASF-H18B4/
C(ZP)
ASF-H24A4/
C(ZP)
ASF-H24B4/
C(ZP)
model
items
Outdoor unit
AS-H18A4/
1
AS-H18B4 AS-H24A4 AS-H24B4
Motor model YDK40-6 YDK40-6 YDK68-6A YDK68-6A
Rotate speed of motor
r/min
850 850 850 850
Motor power W 40 40 68 68
Motor capacitor 2.5 2.5 4.0 4.0
Air blade
(diameter mm)
400 400 440 440
Refrigerant charge
(kg)
1.26 1.32 1.95 2
Refrigerant control / / / /
Working temperature
of the compressor
-7~43 -7~43 -7~43 -7~43
Outdoor
unit
Protection device
Inner
installed
Inner installed
Inner
installed
Inner
installed

Table of Contents