Change the
VLANTEST value
Use the dialpad to enter the new value of the
DHCPOFFER wait period of from 0 to 999, inclusive.
Proceed to the next step.
4. Press Save to store the new setting and redisplay the Craft Local Procedure screen
or Cancel to return to the Craft Local Procedure screen without saving the value
entered.
Once the new values are stored, the telephone is reset.
Calibrating the Touch Screen
Screen calibration properly aligns the touch screen but should only be used for a
significant problem with the touch screen.
Important:
Use a stylus rather than your finger to touch the calibration points precisely.
Note:
The CLEAR Craft procedure clears any calibration data set using the
CALIBRATE SCREEN Craft procedure, but does not affect factory-set calibration
data. Use the Default softkey to restore factory-set calibration. Calibration results
are not saved as part of a backup.
To calibrate the touch screen, use the following procedure:
1. When you select CALIBRATE SCREEN from the Craft Local Procedure Screen, the
telephone displays three softkeys - Start, Default, and Cancel.
2. Take one of the following actions:
• Touch Cancel to return to the Craft Local Procedure screen without calibrating
the screen.
• Touch Default to reset the calibration parameters to the factory-set values, as
evidenced by a confirmation tone and redisplay of the Craft Local Procedure
screen.
• Touch Start to calibrate the screen. A calibration target (+) appears at a
particular point on the screen. Proceed to the next step.
3. Touch the center of the target with the stylus as soon as it appears.
The target disappears, and a new target appears in a different part of the screen.
Calibrating the Touch Screen
H.323 Installation & Maintenance Guide R6.1 May 2011 45