D - BEGINNING OPERATION
• If L1 is off, the photocells are inactive at the
beginning of the opening process. Press “+” to
activate them, then OKtoconrm.AllLEDswill
turnonandofftoconrmtheoperation.
• If L1 is on, the photocells are active at the
beginning of the opening process. Press “–” to
deactivate them, then OK to conrm.All LEDs
willturnonandofftoconrmtheoperation.
3.2.3. TYPE OF GATE
To operate the electronic card on a single-panel
gate, this setting must be changed. By default, this
value is set to 0 (two-panel gate mode).
In addition, the motor output that remains active in
side gate mode is M1 (not to be confused with the
pedestrian passage function).
To activate or deactivate this function, follow
the procedure below
• Press PROG for 3 seconds. L0 will ash once
and L1 will turn on.
• Press PROGfor3seconds.L0willashtwice.
• Press “+” twice and L3 will switch on instead of
L1.
• Press OK.
• If L1 is off, gate mode is activated. Press “+” to
activate side gate mode, then OKtoconrm.All
LEDswillturnonandofftoconrmtheoperation.
• If L1 is on, side gate mode is activated. Press
“–” to activate gate mode, then OKtoconrm.All
LEDswillturnonandofftoconrmtheoperation.
Self-learning is required if this setting is
changed.
3.2.4. STOP TOLERANCE
During self-learning, the system learns the path of
each panel to determine when a panel stops if it
has reached a stop or an obstacle. In fact, during
a movement, if more than a certain percentage of
the path remains to be completed by the panel but
it comes under strain, the system considers it to be
pushing against an obstacle. If the panel comes
under strain when less than such percentage
remains to be completed, the system considers
that the panel has reached its stop. By default, this
percentage is 3%.
However, the accuracy of the system depends on
many parameters, such as temperature, motor
quality,thetypeofmotorcablesandtheexibility
and weight of the gate. Depending on these
parameters, the path measuring system may not
be accurate enough to operate with this default
tolerance. In this case, the system can trigger
obstacle detection when the panels reach their
normal stop. If this occurs (and after conrming
that the opening and closing stops are stable), the
obstacle detection tolerance must be increased.
To adjust this tolerance level, follow the
procedure below
• Press PROG for 3 seconds. L0 will ash once
and L1 will turn on.
• Press PROGfor3seconds.L0willashtwice.
• Press “+” 3 times and L4 will switch on instead
of L1.
• Press OK. The number of LEDs that turn on will
indicate the set value.
• Use the “–” and “+” buttons to change this value.
The higher the value, the higher the tolerance
level (“lower risk of obstacle detection at the
stop”).
• Press OKtoconrmthisvalue.AlltheLEDswill
turnonandofftoconrmtheoperation.
Self-learning is required if this setting is
changed.