MagneW FLEX+/PLUS+ Electromagnetic Flowmeter Detector 2-1
Chapter 2 : Installation
This section describes unpacking, installation and wiring of the MagneW FLEX+/
PLUS+
.
Depending on the grounding ring or piping material, the required parts or the method
of device installation vary.
2.1 : Unpacking
This device is a precision instrument and should be handled with care to prevent
damage or breakage.
WARNING
This detector is heavy. Dropping it could cause personal injury or damage to the
device.
After unpacking the unit, verify that the following items are present:
• MagneW
FLEX+/PLUS+ Detector
• Standard accessories
• Precautions for installation sheet
2.1.1: Verifying specications
The specications for this device are written on its attached identication plate.
Compare these specications with those listed in Appendix A, device standard
specications and model numbers, and verify that all specications on the plate are
correct, paying special attention to the following:
• Detector size
• Electrode material
• Lining material
• Flange rating
• Grounding ring material
If you have questions regarding the specications of your device, contact your nearest
Azbil Corporation oce or the azbil Group representative. When making an inquiry,
be sure to provide the model number and product number of this device.