Installation Azbil Corporation
2-8 MagneW FLEX+/PLUS+ Electromagnetic Flowmeter Detector
Tilted pipe Off-center Off-center
Figure 2-7 Unacceptable positioning
CAUTION
Never attempt to force the detector between two anges if the space is too narrow.
It can damage the detector.
Figure 2-8 Unacceptable placement of detector between anges
CAUTION
Make certain the bore diameters of the pipe and the detector are exactly the same
and install the detector so that the gasket does not protrude into the inner bore of
the pipe, as this could result in leakage or other hazards.
CAUTION
Tighten each bolt a little at a time and apply uniform pressure to all the bolts.
If leakage continues after tightening the bolts, make sure that the pipe is not o
center, then continue to tighten each bolt a little at a time.