MagneW FLEX+/PLUS+ Electromagnetic Flowmeter Detector 2-45
Mounting of the special gasket
Mount the supplied special clamp gasket so that it ts into the groove of the gasket.
WARNING
Mount it carefully into the groove so that there is no misalignment of the gasket.
Misalignment can cause leakage or other hazards. Gaskets and clamps are
attached to sanitary model MGS18U.
Direction of installation
Match the ow direction of the measured uid to that of the ow direction mark of
the detector, and insert the detector between the ferrules.
IDF-clamp / Tri-clamp tightening
Mount the clamp so that it will cover the detector and the tapered section of the
ferrule, and screw it tightly.