Advanced
Encoder Protocol Protocol Type The Protocol Type enables the encoder interface. Selecting V1 or V2
automatically configures the Digital Input and Digital Output #1 for
encoder operation. Manually configuring the input and output for encoder
operation is not allowed and results in an error.
See “Encoder Protocol Interface” on page 57 for further details.
V1 – Standard encoder protocol
V2 – Enhanced encoder protocol, provides additional digital information
Disabled – disables and removes encoder configuration
Totalizer Dials Set the totalizer dial to 4…10 to select the number of digits for the totalizer to display. For example,
setting the dial to 6 causes the totalizer to display six digits (12.3456 USG)
OTE: N A totalizer roll over can be indicated by a totalizer alarm via the digital output.
Totalizer
Resolution
[Off]
U
Use Totalizer Resolution to establish the number of units of measure that have to accumulate before
the display totalizers are updated. This is also known as setting the number of “dead” zeroes in the
display totalizer. For example:
Totalizer Resolution less than 1
Totalizer
Resolution
Example
OFF 0.00000 USG 0.00012 USG 0.00123 USG 0.01234 USG 0.12345 USG
0.0001 0.0000 USG 0.0001 USG 0.0012 USG 0.0123 USG 0.1234 USG
0.001 0.000 USG 0.000 USG 0.001 USG 0.012 USG 0.123 USG
0.01 0.00 USG 0.00 USG 0.00 USG 0.01 USG 0.12 USG
0.1 0.0 USG 0.0 USG 0.0 USG 0.0 USG 0.1 USG
Totalizer Resolution greater than or equal to 1
Totalizer
Resolution
Example
OFF 0.00000 USG 1.23456 USG 12.34567 USG 123.4567 USG 1234.456 USG
1 0 USG 1 USG 12 USG 123 USG 1234 USG
10 0 USG 0 USG 10 USG 120 USG 1230 USG
100 0 USG 0 USG 0 USG 100 USG 1200 USG
1000 0 USG 0 USG 0 USG 0 USG 1000 USG
To change the Totalizer Resolution, follow these steps from the Advanced menu:
1. Select Totalizer Resolution to view the Totalizer Resolution display.
2. Select a resolution.
3. Press [E] to save the option and to return to the Advanced menu.
Backlight Control
[Timed Off]
U
Use Backlight Control to set the backlight to: Always On, Always Off or Timed Off.
When set to Timed Off, the backlight automatically turns off after one minute of inactivity (no buttons
pressed). Pressing any button turns the backlight on, but does not immediately navigate the menu.
To change Backlight Control, follow these steps from the Advanced menu:
1. Select Backlight Control to view the Backlight Control display.
2. Select an option.
3. Press [E] to save the option and to return to the Advanced menu.
Longer operation with the backlight set to “Always On” can reduce LCD lifespan.
Using the Main Menu Programming Options
Page 49 March 2022 MAG-UM-01272-EN-21