3.5.3 Motor cable pin configuration - Baldor linear motors
The following table shows the pin colors used in a typical Baldor linear motor cable set, part
number AY1763A00:
Signal name
Motor cable wire color
Motor U Black
Motor V Red
Motor W White
Motor ground Green
Thermal switch Blue
Thermal switch Orange
Signal name Hall cable wire color
Hall 1 (U) White
Hall 2 (V) Red
Hall 3 (W) Black
Hall ground Green
Hall +5VDC Brown
3.5.4 Sinusoidal filter
A sinusoidal filter is used to provide a better quality waveform to the motor, reducing motor noise,
temperature and mechanical stress. It will reduce or eliminate harmful dV/dt values (voltage rise
over time) and voltage doubling effects which can damage motor insulation. This effect occurs
most noticeably when using very long motor cables, for example 30m (100 ft) or more. Baldor
motors intended to be used with drives are designed to withstand the effects of large dV/dt and
overvoltage effects. However , if very long motor cables are unavoidable and are causing
problems, then a sinusoidal filter may be beneficial.

Table of Contents

Other manuals for Baldor MicroFlex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baldor MicroFlex and is the answer not in the manual?

Baldor MicroFlex Specifications

General IconGeneral
BrandBaldor
ModelMicroFlex
CategoryAmplifier
LanguageEnglish

Related product manuals