EasyManuals Logo

Baldor MicroFlex Installation Manual

Baldor MicroFlex
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
www.baldormotion.com
5-14 Input / Output MN1919
5.4 Serial po rt - X6
Location Connector X6
Pin RS232 name RS485 / RS422 name
1 (NC) (NC)
2 RXD RX- (input)
3 TXD TX- (output)
4 (NC) (NC)
5 0V GND 0V DGND
6 (NC) (NC)
7 RTS TX+ (output)
8 CTS RX+ (input)
9 (NC) (NC)
Description RS232 or RS485 / RS422 connections on a 9-pin male
D-type connector
MicroFlex is available with either an RS232 or RS485 serial port (see section 2.2.1). The port
is fully ESD protected to IEC 1000-4-2 (15kV).
5.4.1 Using RS232 cable
The MicroFlex has a full-duplex RS232 serial port with the following preset configuration:
H 57.6 Kbaud
H 1startbit
H 8 data bits
H 1stopbit
H No parity
H Hardware handshaking lines RTS and CTS must be connected.
MicroFlex
(DTE)
9-pin
Computer
COM Port
(DTE)
X6
RXD 2
TXD 3
GND 5
2RXD
3TXD
5GND
RTS 7
CTS 8
7RTS
8CTS
COM
Connect overall shield
to connector backshell.
Figure 38 - RS232 serial port connections
When the MicroFlex is connected to Mint WorkBench, the Tools, Options menu item can be
used to configure the serial port. The configuration can also be changed using the Mint
keyword SERIALBAUD (see the Mint help file for details).
1
5
6
9

Table of Contents

Other manuals for Baldor MicroFlex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baldor MicroFlex and is the answer not in the manual?

Baldor MicroFlex Specifications

General IconGeneral
BrandBaldor
ModelMicroFlex
CategoryAmplifier
LanguageEnglish

Related product manuals