www.baldormotion.com
8-6 Specifications MN1919
8.1.12 Encoder output (simulated) (X7)
Unit All models
Signal RS422
Resolution
with encoder input on X8
with SSI encoder input on X8
Output is a copy of the input on
X8.
Adjustable simulated output.
See section 4.1.4.
8.1.13 Serial RS232/RS485 interface (X6)
Unit All models
Signal RS232, non-isolated CTS/RTS
or
RS485, non-isolated
(model dependent)
Bit rate baud 9600, 19200, 38400,
57600 (default)
8.1.14 Environmental
All models Unit All models
Operating temperature range* °C °F
Minimum
Maximum
Derate
+0
+45
See sections
3.2.2 to 3.2.6
+32
+113
See sections
3.2.2 to 3.2.6
S torage tempe rature range* -40to+85 -40to+185
Humidity (maximum)* % 93
1A, 3A 6A 9A
Forced air cooling flow
(vertical, from bottom to top)
m/s None required 1 2.5
Maximum insta lla tion altitude
(above m.s.l.)
m
ft
1000
Derate 1.1% / 100m over 1000m
3300
Derate 1.1% / 330ft over 3300ft
Shock* 10G
V ibration* 1G, 10-150Hz
IP rating IP20**