EasyManua.ls Logo

Baldor MicroFlex - Page 55

Baldor MicroFlex
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.baldormotion.com
Input / Output 5-3MN1919
AIN0
(ADC.0)
X3
GND
AIN0
(ADC.0)
13
12
14
X3
AIN0-
Differential connection Single ended connection
AIN0+
AIN0+
13
12
14
Figure 25 - AIN0 analog input wiring
AIN0
1k, 0.25W
potentiometer
(ADC.0)
X3
1.5k, 0.25W
0V
+24VDC
13
12
14
Figure 26 - Typical input circuit to provide 0-10V (approx.) input from a 24V source
NextMove ESB / controller
Demand0
AGND
1
2
13
12
MicroFlex
AIN0+
AIN0-
Connect overall shield at
one end only
3
Shield
-
+
‘X3’‘X13’
14
AGND
Figure 27 - Analog input - typical connection from a Baldor NextMove ESB

Table of Contents

Other manuals for Baldor MicroFlex

Related product manuals