Banner AG4 Series Safety Laser Scanner
Scanner has optical glare caused by another device.
Switch off the supply voltage and start the Scanner again.
Motion Monitor, Field Pair activated wrong several
times. Speed exceeding can no longer be corrected.
Check the activation of the Protective Fields in the speed matrix and the
speed the vehicle moved at.
Motion Monitor, speed very much exceeded.
Exceeding cannot be corrected.
Check the activation of the Protective Fields in the speed matrix and the
speed the vehicle moved at.
Motion Monitor, maximum speed exceeded or wrong
Field Pair activation. Cannot be corrected.
Check the activation of the Protective Fields in the speed matrix and the
speed the vehicle moved at.
Motion Monitor, activated Field Pair was not released
in the configuration.
Check the activation of the Protective Fields in the speed matrix and the
program wizard.
Motion Monitor, error on the Field Pair control inputs.
Activated Protective Field not defined.
Check the activation of the creep and further travel blocking functions.
Motion Monitor, further travel blocking cannot switch off
the safety outputs or switching function (OSSDs).
Check the connection/wiring of the OSSDs.