Numeric ID Text ID Description
10350 ARGUMENTS_DETECTED Get command received with unneeded arguments
10351 INVALID_ARGUMENT_TYPE Item ID specified must be an item (not a group or method)
10500 DATA_SET_EMPTY Data export operation returned no results.
10900 SENSOR_NOT_READY Command specified requires iVu BCR to be in the READY state.
10920 SENSOR_TYPE_NOT_ACTIVE Command specified belongs to a different sensor type.
10950 DEVICE_TYPE_INVALID Command not supported on this device type.
15000 VALUE_INVALID Text value is invalid / unknown
15050 VALUE_INVALID Text value is invalid - expecting True or False
15100 STRING_TOO_LONG String value specified exceeds maximum allowable length
20002 COMPARE_DATA_DISABLED Operation requires Barcode compare to be enabled
20003 COMPARE_MASK_INVALID Compare mask invalid. Expecting string of 1's and 0's with length
equal to compare data string
20004 NUMBER_TO_FIND_NOT_ONE Barcode number to find must be set to one for this operation.
20005 COMPARE_MASK_DISABLED Operation requires Barcode compare mask to be enabled.
80000 REMOTE_DISPLAY_NOT_CONNECTED Remote Display must be connected to obtain this value
80001 REMOTE_DISPLAY_NOT_SUPPORTED This device does not have Remote Display capability
80100 COMMAND_MODE_EXPECTED The Trigger Mode must be set to "Command" perform this
operation
80101 COMMAND_TIMED_OUT The command timed out before finishing
80102 TRIGGER_REQUIRED Access to the specified data requires a triggered inspection
80150 COMMAND_TIMED_OUT The command timed out before finishing
80200 SYSTEM_ERROR_NOT_ACTIVE The System Error must be active to execute this command
80350 MULTIPLE_INSPECTIONS_DISABLED Requires multiple inspections to be enabled
80351 MULTIPLE_INSPECTIONS_EMPTY No inspections are available in multiple inspection mode.
80400 PRODUCT_CHANGE_WHEN_NOT_READY Sensor must be in the READY state to perform a product change.
80401 PRODUCT_CHANGE_INVALID_INSPECTION Attempt to product change to an unknown or invalid inspection.
80402 PRODUCT_CHANGE_TIMEOUT The Product Change operation timed out.
80403 PRODUCT_CHANGE_TO_SAME_INSPECTION Attempt to product change to the same inspection.
80404 SENSOR_NAME_NOT_FOUND Attempt to use a command without a sensor name in a multi-
sensor inspection
Examples of Operation
The following examples show how to utilize the iVu BCR Command Channel via the Industrial Ethernet connection.
Clear System Error
1. Write the number 81 as a 16-bit integer into the Command ID register.
2. Toggle the Command bit from 0 to 1 (bit 15 in the Input Bits/Input Coil Bits register).
3. Wait for the Command ACK
flag to go from 0 to 1 (bit 15 in the Input Bits ACK/Input Coil Bits ACK register).
4. Verify that the Execution Error flag is not set (that is, the value should be 0). This is bit 15 in the Output Bits/Status
Coil Bits register. If the value is 1, read the Error Code register for more information.
5. Task Complete. Toggle the Command bit back to 0 (bit 15 in the Input Bits/Input Coil Bits register).
Get/Set Trigger Mode
Get the current Trigger Mode from the iVu BCR.