AW00097603000 Standard Features
Basler aviator GigE 207
When the next frame start trigger is received, the camera advances to the next sequence set:
The parameter values of sequence set 1 are used for the image acquisition.
When the next frame start trigger is received, input line 1 is found to be high. Accordingly,
another sequence set cycle is started and the parameter values of sequence set 0 are used for
the image acquisition. As explained above, synchronous restart has priority here over the
automatic sequence set advance.
When the next frame start triggers are received, the camera advances to the next sequence
sets and uses them for image acquisition in accord with the Always Active sequence control
source and as described in the previous use case.
Make sure not to send a frame start trigger while the input line changes its
state. During this period, the camera will not wait for a frame start trigger and
any frame start trigger will be ignored.
Make sure to only send a frame start trigger when the camera is in "waiting for
frame start trigger" status.
For information about possibilities of getting informed about the "waiting for
frame start trigger" status, see the Acquisition Monitoring Tools section.