AW00097603000 Standard Features
Basler aviator GigE 213
When the next frame start trigger is received, the camera checks the states of input lines 2 and
1. Input line 2 is found to be low and therefore the sequence cycle is not restarted. Input line 1
is found to be high and therefore the parameter values of the next sequence set are loaded
into the active set. The parameter values of sequence set 1 are used for the image acquisition.
When the next frame start trigger is received, the camera checks the states of input lines 2 and
1. Input line 2 is found to be low and therefore the sequence cycle is not restarted. Input line 1
is found to be high and therefore the parameter values of the next sequence set are loaded
into the active set. The parameter values of sequence set 2 are used for the image acquisition.
When the next frame start trigger is received, the camera checks the states of input lines 2 and
1. Input line 2 is found to be low and therefore the sequence cycle is not restarted. Input line 1
is found to be high and therefore the parameter values of the next sequence set are loaded
into the active set. The parameter values of sequence set 3 are used for the image acquisition.
When the next frame start trigger is received, the camera checks the states of input lines 2 and
1. Input line 2 is found to be high and therefore the sequence cycle is restarted. Input line 1 is
found to be high but this has no significance: Synchronous restart has priority over the
secquence set advance control. The parameter values of sequence set 0 are used for the
image acquisition.
Another sequence set cycle has started.
When the next frame start trigger is received, the camera checks the states of input lines 2 and
1. Input line 2 is found to be low and therefore the sequence cycle is not restarted. Input line 1
is found to be high and therefore the parameter values of the next sequence set are loaded
into the active set. The parameter values of sequence set 1 are used for the image acquisition.
When the next frame start trigger is received, the camera checks the states of input lines 2 and
1. Input line 2 is found to be low and therefore the sequence cycle is not restarted. Input line 1
is found to be low and therefore no new sequence parameter values are loaded into the active
set. The parameter values of sequence set 1 are used for the image acquisition.
Make sure not to send a frame start trigger while an input line changes its
state. During this period, the camera will not wait for a frame start trigger and
any frame start trigger will be ignored.
Make sure to only send a frame start trigger when the camera is in "waiting for
frame start trigger" status.
For information about possibilities of getting informed about the "waiting for
frame trigger" status, see the Acquisiton Monitoring Tools section.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler GigE CAMERAS and is the answer not in the manual?

Basler GigE CAMERAS Specifications

General IconGeneral
BrandBasler
ModelGigE CAMERAS
CategoryDigital Camera
LanguageEnglish

Related product manuals