7.2.1 Switching the unit on
First commissioning has been performed correctly, see Chapter 7.1.2 Starting
up the unit for the first time, Page 60.
The unit has been prepared correctly for commissioning, see Chapter 7.1.1
Checks before each commissioning, Page 59.
All covers are kept closed.
1.
Open the condensate drain cocks to allow the pressure to dissipate and to al-
low the engine to start under zero load.
The compressor is automatically unloaded on units with automatic condensate
drain.
Fig. 15 Open the condensate drain cocks
1 Condensate drain cock 3 Condensate drain cock
2 Condensate drain cock
2.
For units with electric motor: Set main switch to I.
- Or -
For units with petrol engine: Open the fuel tap. Set ignition switch to I. Set the
choke on the petrol engine to Start and start the engine using the pull starter.
As soon as the engine starts and is running smoothly, set the choke to Run.
7 | Commissioning and operation
OPERATING MANUAL
64/106
A_Compact-Line_002_en
10-10-2016