EasyManua.ls Logo

Bauer Compact-Line JUNIOR II-B - Switching the Unit off

Bauer Compact-Line JUNIOR II-B
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
1
2
5
3
Fig. 16 Starting units with petrol engine
1 Choke 4 Petrol engine
2 Pull starter 5 Ignition switch
3 Fuel tap
3.
Close the condensate drain cocks and run the unit to final pressure.
4.
Check the final pressure safety valve and pressure gauge.
5.
Open the condensate drain cocks and drain the condensate when the final
pressure is reached.
Ä
The unit is ready for filling.
7.2.2 Switching the unit off
1.
Close filling valve.
2.
For units with electric motor: Set main switch to 0.
- Or -
For units with petrol engine: Set the ignition switch to 0 and close the fuel tap.
3.
Drain the condensate.
4.
De-pressurize the unit to approx. 50-80 bar using the filling valve.
5.
Close the condensate drain cocks and filling valve to prevent moisture from
penetrating and causing saturation of the filter cartridge.
OPERATING MANUAL
Commissioning and operation | 7
10-10-2016
A_Compact-Line_002_en
65/106