9.13 Maintenance activities - Automatic condensate drain
9.13.1 Checking the function of the automatic condensate drain
WARNING
Danger of injuries due to the gas escaping at high pressure!
Wear protective goggles and personal ear defenders.
After a water removal operation has been carried out by the automatic conden-
sate drain, open the condensate drain cock of the automatic condensate drain.
Ä
If almost no condensate is emerging, it means that the automatic conden-
sate drain is working properly.
Is a lot of condensate emerging?
The automatic condensate drain or the condensate drain valve is not working prop-
erly.
Find the fault and eliminate it.