9.9 Maintenance activities for filling equipment
9.9.1 Maintaining the filling valves
A sintered filter in the filling valve body protects the filling valve from contamina-
tion.
Dismantle and clean the sintered filter of the filling valve as follows; in case of se-
vere contamination, replace it if necessary:
The compressor unit is switched off.
The compressor unit is secured against restarting.
WARNING
Danger of poisoning due to contaminated breathing air!
Ensure cleanliness and hygiene.
Only use cleaning agents and sealant that are suitable for breathing air.
1
2
3
Fig. 24 Maintaining the sintered filter
1 Filling valve 3 Pressure gauge
2 Sintered filter
1.
De-pressurise the compressor unit, see Chapter 9.4 De-pressurising the unit,
Page 81.
2.
Unscrew the pressure gauge from the filling valve body.
3.
Unscrew the sintered filter using an adequately wide screwdriver.