7.2.6 Filling operation
DANGER
Danger of poisoning due to pollutants in breathing air!
Inhaling harmful gases can be dangerous to life.
Make sure that the air drawn in is free from toxic gases, exhaust gases or sol-
vent vapours.
Do not fill breathing air cylinders with air from workrooms.
Do not fill breathing air cylinders if the air drawn has a CO component of more
than 25 ppmV (parts per million by volume). This is applicable even when us-
ing a CO filter cartridge.
After a standstill period of more than 6 hours, flush the compressor unit be-
fore connecting breathing air cylinders.
Flushing the unit
CAUTION
Danger of injury due to loud noises!
Wear ear defenders.
1.
Switch on unit.
2.
Secure the filling valve, point it downwards and open it slowly.
3.
Release the compressed air into the atmosphere for 2 minutes.
4.
Close filling valve.
Ä
The unit is ready for the filling operation.