7.2.3 Behaviour in case of emergency
Switching the unit off in case of an emergency
The unit is equipped with at least one emergency stop switch, see Chapter 2.4.7
Safety and monitoring equipment, Page 23.
Press the emergency stop switch.
Ä
The control voltage will be interrupted.
Restarting the unit after an emergency
The emergency situation no longer exists. The cause has been rectified.
1.
Turn the red button of the emergency stop switch clockwise.
2.
If applicable, reset the alarm message on the control unit.
3.
Switch the unit on.
7.2.4 Monitoring operation
1.
For units without an operating hours counter: Note the operating hours down
in order to ensure precise compliance with the maintenance intervals.
2.
Monitor the operating hours to observe the permissible cartridge idle times of
the filter system, see Chapter 9.7 Maintenance activities - Filter system,
Page 86.
3.
Monitor the number of load cycles to adhere to the permissible load cycle
numbers of pressure vessels, see Safe handling of pressure vessels, Page 22.
If there is no automatic cycle counter: Note down the number of load cycles
run.
4.
Drain condensate every 15 minutes.
- Or -
For units with an automatic condensate drain, ensure that it drains water off
every 15 minutes.
7 | Commissioning and operation
OPERATING MANUAL
66/106
A_Compact-Line_002_en
10-10-2016