9.7.2 Changing the cartridge of the fine after-cleaner
When the system has been used for the maximum permissible number of operating
hours, the cartridge must be replaced.
Vacuum packing of the cartridge is undamaged.
Special filter spanner (part of the scope of supply).
A clean cloth is provided.
A suitable grease for breathing air application is available, see Chapter 9.3.3
Lubricant, Page 79.
WARNING
Danger of injury due to high pressure in the pressure vessel!
De-pressurise the pressure vessel before carrying out any maintenance activi-
ties on it.
WARNING
Danger of poisoning due to contaminated breathing air!
Ensure cleanliness and hygiene.
Only use cleaning agents and sealant that are suitable for breathing air.
WARNING
Danger of poisoning due to unfiltered air!
When they are in mint condition, the filter cartridges are vacuum-packaged and
capable of being stored for two years (see durability date on the filter cartridge).
Defective vacuum packing or an overshot durability date cannot protect the filter
cartridge adequately from environmental influences in storage. Under such cir-
cumstances, the filter cartridge can be saturated before it is used.
Only use filter cartridges with undamaged vacuum packing.
Do not use filter cartridges with overshot durability date.
1.
De-pressurise the unit, see Chapter 9.4 De-pressurising the unit, Page 81, and
drain the condensate.
2.
Use the special filter spanner tool to unscrew and remove the filter head.
3.
Pull the cartridge out of the filter using the bracket.
OPERATING MANUAL
Maintenance | 9
10-10-2016
A_Compact-Line_002_en
87/106