The B-TIMER shows the following information:
Main menu
Remaining filter capacity in percent
Number of operating hours until service interval A (500 hours or yearly)
Number of operating hours until service interval B (1000 hours or every 2
years)
Number of operating hours until service interval C (2000 hours or every 4
years)
Filter cartridge number (the filter icon blinks)
Press the selection key to toggle between the displays.
Resetting the B-TIMER
The filter cartridge was replaced or corresponding maintenance activities have
been carried out.
1.
Switch to the corresponding display to reset the filter capacity of maintenance
interval A, B, C.
2.
Press the input key on the corresponding display for longer than 5 seconds.
7 | Commissioning and operation
OPERATING MANUAL
68/106
A_Compact-Line_002_en
10-10-2016