Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
102
of 208
4.3
P1149
Please note the ACI3/AVI4 switch on the option card.
This parameter selects between ACI3 and AVI4.
For further information see ZP1139– and ZFigure 48– on page 100.
P1150
For further information see ZP1139– or ZP1149– and ZFigure 48– on page 100.
P1151
The parameter are used to set the analog input reference values and is based on percent-
age of ZP0033–).
For further information see ZP1139– or ZP1149– and ZFigure 48– on page 100.
P1152
For further information see ZP1139– or ZP1149– and ZFigure 48– on page 100.
P1153
The parameter are used to set the analog input reference values and is based on percent-
age of ZP0033–).
For further information see ZP1139– or ZP1149– and ZFigure 48– on page 100.
P1149
ACI3/AVI4 Auswahl für AI2 0 to 1
EE ACI3/AVI4 selection for AI2 terminal mode 0
STOP BM_u_AI2ModeACI3AVI4Selection 1:1
Value Meaning
0 ACI3: analog current (0.0 to 20.0 mA)
1 AVI4: analog voltage (0.0 to 10.0 V)
P1150
Minimale AVI4 Spannung 0.0 to 10.0 V
EE Minimum AVI4 voltage 0.1 V
STOP BM_u_MinimumAVI4Voltage 10:1
P1151
Minimale AVI4 Frequenz 0.0 to 100.0 %
EE Minimum AVI4 frequency 0.0 %
STOP BM_u_MinimumAVI4Frequency 10:1
P1152
Maximale AVI4 Spannung 0.0 to 10.0 V
EE Maximum AVI4 voltage 0.1 V
STOP BM_u_MaximumAVI4Voltage 10:1
P1153
Maximale AVI4 Frequenz 0.0 to 100.0 %
EE Maximum AVI4 frequency 0.0 %
STOP BM_u_MaximumAVI4Frequency 10:1