BDCOM S6508 Switch Hardware Installation Guide
prompt: Source file name[]?boot.bin
prompt: Remote-server ip address[]?192.168.20.1
please wait ...
###################################################################
###
###################################################################
###
###################################################################
###
#############################################
TFTP:successfully receive 524288 bytes
Please wait for update Bootrom...
Successfully update Bootrom
monitor#
4.5.4 upgrade in CLI(command line interface)
In order to convenient to upgrade software for on-line manufacture, the system
software provide that upgrade the system software itself and Bootrom software. The
method is similar with that on monitor mode.
1. Use TFTP protocol:
(1) Run system software, enter privilege mode:
switch#
(2) Enter into config mode, config a ip address to a enternet port.
switch#
config
switch_config#
int vlan 1
switch_config_v1#
ip address <ip_addr> <net_mask>
(3) Use PING to test connection between tftp server and you computer .
switch#
ping <ip_address>
<ip_address>: target ip address, that is tftp server ip address.
(4) Install or upgrade system software by TFTP protocol
switch#
copy tftp flash [ip_addr]
(5)
After upgradation, return to command line prompt interface.
- 51 -