30 en | System configuration BIS 2.3 - Access Engine
F.01U.028.713 | V 2.3.0.1 | 2009.11 Installation manual Bosch Sicherheitssysteme GmbH
2. In the BIS Manager switch to the Load/Save configuration
page.
–In the Load new configuration field click the ellipsis
button () and select the directory with the new
configuration.
Check that the paths in the Configuration display
field are correct and press the Load button beneath.
Confirm the confirmation prompt about the
configuration change with Yes.
Answer Yes to the question regarding the system (BIS
Server component) start.
While changing the configuration change a progress dialog is
shown, followed by confirmation of completion.
1. Close the confirmation of completion by clicking the Close
button.
4.4 Copying configuration changes
If the changes were made when the BIS Server was not running,
then the changes just need to be saved using the Apply buttons
in the Configuration Browser dialogs. The current settings will
be loaded automatically when the system is started.
However, if changes are made while the system is running,
these do not come into effect until the changed configuration is
reloaded. To load a changed configuration follow steps 2 and 3
in Section 4.3 Loading a configuration, Page 29.
i
NOTICE!
If the BIS Manager is already running with a configuration, the
question regarding the system start is omitted and the
configuration change starts immediately.
i
NOTICE!
If the platform has been started on a workstation, any BIS user
who is logged on will be automatically logged off with a
message informing him of the configuration change.