9 Setting System Parameters with
SPEdit
The default Access Engine system settings will satisfy most
customer requirements.
Nevertheless it may be desirable in some cases to change the
default settings above and beyond that which can be
customized in the BIS Configuration Browser. For this pupose
Access Engine provides the ACE System Parameter Editor
(SPEdit), which makes Windows registry changes for the
Access Engine application.
9.1 Starting the SPEdit
You can only start SPEdit from the BIS Configuration Browser.
1. In BIS Manager, click the Start button beside
Configuration Browser on the first tab.
2. Click on one of the following entries:
In the field Recent configurations choose the desired
entry.
–In the field Configuration management click
on Open a configuration if you want to browse for it
or
on Open current configuration if you want to see the
currently used parameters.
3. Login to Configuration Browser.
4. Select the Tools menu.
5. Select the ACE System Parameter Editor entry in the top
left window.
6. Click the System Parameter Editor button to open the
program.