1 691 606 210 2015-07-29| Robert Bosch GmbH
56 | BSA 43xx | Manual mode (normal operation)en
Step Remote control unit Result / Display
5. Change the frequency and listen for
noise.
i The frequency can be altered in the
range 10-30 Hz.
0.5 Hz higher
0.5 Hz lower
The current frequency is displayed on the
screen.
"The measured values can now be stored. Refer
to Section 5.6.2. A maximum of 4 frequencies
can be stored per wheel.
6. Drive vehicle out of noise simulator.
"Noise measurement is over.
5.2.5 Side slip tester SDL 410
Step Result / Display
1. Check prerequisites:
R No vehicle on dynamometer!
R Tester/test routine selected.
Left: "Side slip tester" device symbol.
Right: Drive-on prompt.
Ready for toe measurement.
2. Keeping the vehicle straight, drive both axles at a
constant speed over the side slip tester. Speed max.
15 km/h.
Front axle toe is measured.
Peak value display (approx. 5 seconds):
$ Toe value (<-->).
"The measured values can now be stored. Refer to
Section 5.6.2.
"Toe measurement is over.