1 691 606 210 2015-07-29| Robert Bosch GmbH
Super automatic mode | BSA 43xx | 65 en
7. Super automatic mode
i Super automatic mode is recommended for full
testing of a vehicle requiring verification of the
measured data.
Features of super automatic mode:
R Specified test sequence (sub-tasks).
R Automatic starting of measurements.
R Automatic storage of measurement results.
R Automatic print-out of measurement results.
i The following applies in super automatic mode:
$ Termination of the test sequence (Automatic but-
ton or STOP) causes all the stored values to be
deleted (Clear All).
$ If the test sequence is not continued, the BSA 43xx
returns to manual mode after approx. 5 minutes.
The stored values are deleted (Clear All).
$ Auto-termination of the order after a pre-config-
ured time period.
i Special features of SDL 410 test sequence
$ Automatic resetting of incorrect measurements:
If no subsequent measurement is taken, the first
toe measurement is identified as an incorrect
measurement and is rejected.
7.1 Mode activation and deactivation
Step Remote control unit Result / Display
¶ Activate super automatic mode.
+
Press one after the other
Mode indicator:
"Super automatic" symbol
¶ Deactivate super automatic mode.
Press STOP
Mode indicator:
"Manual mode" symbol
7.2 Test sequence
Step Result / Display
1. Check prerequisites:
R No vehicle on dynamometer!
R Tester/test routine selected.
R "Super automatic" mode selected.
! It is essential to comply with the test sequence
(sequence of sub-tasks)!
Left: Device identifier and current sub-task:
1 = Front axle.
2 = Rear axle.
P = Parking brake.
Right: Drive-on prompt.
The rest of the test sequence is similar to Automatic mode (Section 6).