EasyManua.ls Logo

Bosch Rexroth IndraMotion MTX micro - Data backup with the HMI software

Bosch Rexroth IndraMotion MTX micro
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 11-1: Archiving procedure in IndraWorks Engineering
11.1.3 Data backup with the HMI software
Backing up data on the USB flash drive/CF card
The HMI software offers a convenient tool for making a backup of all user da‐
ta of a machine.
From version 13
Proceed as follows to make the data backup:
1. Insert a USB flash drive into the port on the VDP80 control panel. After it
has been registered by the system, an appropriate message is dis‐
played. Omit step 1, if data is only to be backed up on the CF card.
2. Switch to the <Maintain> operating area
3. Press the <F8> (Backup) key
4. Select <F7> (Operator) UserBackup or <F8> (OEM) Backup when log‐
ged in as MTB or Developer, otherwise, the query is not displayed.
5. Press <F8> (Yes) to start the data backup.
6. Wait until the "Backup done" message is displayed, which may take up
to 15 minutes.
Bosch Rexroth AG DOK-MTXMIC-EASY*******-CO06-EN-P148/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Data backup and serial commissioning

Table of Contents

Other manuals for Bosch Rexroth IndraMotion MTX micro

Related product manuals