Editing drive parameters
Fig. 10-16: Drive parameter editor (13VRS)
Proceed as follows to edit a drive parameter:
1. Log in as OEM or Developer user
2. Switch to the <System> operating area
3. ● From Version 12:
Press <F2> (Para.)
Press <F7> (DrPara)
● Version 10:
Press <F3> (DrivePar)
4. Press <TAB> to move to the parameter number input field
5. Enter the desired parameter number (e.g., S100 or P12)
6. If necessary, switch the drive phase to <Phase2> using the machine
keys
7. Editing parameters
8. Switch the drive phase back to <Phase4>
10.2.6 User management
The HMI software features a user management which can be used to control
the rights to operation and the rights to edit data.
There are 4 user levels:
● Guest: Can select and start NC programs, but cannot be used to edit
programs or parameters
● Operator: Same as "Guest", but is additionally allowed to edit programs
and tools
● OEM: Same as "operator", but is additionally allowed to save and back‐
up data and edit parameters
● Developer: No restrictions
Bosch Rexroth AG DOK-MTXMIC-EASY*******-CO06-EN-P144/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Operating the IndraMotion MTX micro