-F1 Line fuse
HNL Line reactor
-K1 Line contactor
Fig. 5-28: Recommended arrangement of components in the control cabinet
● Run cables and lines for control signals and power signals in
separate cable ducts.
● Use shielded Rexroth cables and lines for connecting motors
and encoders.
● Make absolutely sure that you adhere to the grounding con‐
cept and specifically that you use a low-resistance protective
conductor connection.
● It is only allowed to install the HC*02 in a vertical position
(G1).
Hot parts with temperatures higher than
105 °C may result in material damage!
● Keep the specified minimum distances from other components.
● Materials present above the devices may only be materials which are in‐
combustible and insensitive to the high temperatures that occur.
Bosch Rexroth AG DOK-MTXMIC-EASY*******-CO06-EN-P58/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Selecting and connecting the hardware