Solution 6000-IP
20
Bosch Security Systems 10/22 BLCC615R
Quick Start Guide
Defaulting The System
Defaulting the system will reset all programming options
back to the factory default setting. All programming
information will be erased.
To Hardware Default
1. Remove all power to the system - AC and battery.
2. Press and hold the default push button, then apply
power to the control panel.
3. Release the default button, The panel will reset and
revert to normal operation when default is complete.
To Software Default
1. Enter programming mode.
[1][2][3][4] + [MENU]
2. Select factory default option.
MENU 7-0-4
3. The panel will reset and revert to normal operation
when the default is complete.
i
Note
You can disable factory defaulting using MENU 7-7-
4. If factory defaulting has been disabled you must
know the installer code to perform a factory default
otherwise the system will need to be returned to
your supplier for defaulting or you can purchase a
CM255B Default Unlock Key which will unlock the
panel in the field. Charges apply for defaulting if
retuned to the distributor.
Direct Link Programming
The panel can be programmed via the Solution Link
Upload/Download software in either Direct Link or Remote
Link modes. For Direct Link you will need a CM900B Direct
Link module which connected the panels serial port to the
PC.
Once the cable is connected you will need to hold down
the default switch on the panel for 5 seconds to initiate the
programming session. See Figure 20: for the default switch
location. It is also possible to initiate the programming
session via MENU 5-0-5 - Start Direct Link.
Zone Array
The feature allows you to view the condition of all zones on
the panel in banks of 16 zones at a time. From the installer
programing mode press MENU 3-0-1 to access the zone
array.
Use the [] and [] arrow keys to scroll up and down the
zone banks and press [OK] or [MENU] when finished.
The following information can be displayed depending on
the current zone status.
N= NORMAL
S = SHORTED
A= ALARM
T= TAMPER
- = DISABLED
0000000001111111
1234567890123456
NSA-ANAT--------
PRESS , OK or MENU
In the above example screen,
N = Zone 01 and 06 are Normal (Sealed)
S = Zone 02 is Shorted
A = Zone 03,05,07 are in Alarm (Unsealed)
T = Zone 08 is in Tamper Alarm (Unsealed)
- = Zone 04, 09-16 are Disabled (Unused)
Door Array
This feature allows you to view door status in groups of 16.
From the installer programing mode press MENU 4-0-4 to
access the door array.
Press [OK] or [MENU] when finished.
The following information can be displayed depending on
the current door status.
L = Door Locked
U = Door Unlocked
O = Override
- = Disabled or Not Available
0000000001111111
1234567890123456
LLLLL---UUUUO---
Press  OK or MENU
In the above example screen,
L = Doors 01 to 05 are Locked
O = Door 13 has a Override condition
U = Doors 09 to 12 area Unlocked
- = Doors 06 to 08 and Doors 14 to 16 are Disabled or
Not Available