EasyManua.ls Logo

Bosch Solution 6000-IP CC615GWF - Myalarm Options; Swinger Dialler; TX Format Dest 1

Bosch Solution 6000-IP CC615GWF
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solution 6000-IP
38
Bosch Security Systems 10/22 BLCC615R
Quick Start Guide
Comms > Reporting >
TX Format Dest 1
MENU 5-4-0
0 0
00 - Disabled 01 ~ 12 Reserved
13 - Ethernet/WiFi 14 - GPRS IP
15 - MyAlarm IP
Use [] and [] keys or enter 0 – 15 then press [OK] to
program the transmission format the control panel will
use to report to Destination 1. Only 1 option can be
programmed.
Comms > Reporting >
TX Format Dest 2
MENU 5-4-1
0 0
00 - Disabled 01 ~ 12 Reserved
13 - Ethernet/WiFi 14 - GPRS IP
15 - MyAlarm IP
Use [] and [] keys or enter 0 – 15 then press [OK] to
program the transmission format the control panel will
use to report to Destination 2. Only 1 option can be
programmed.
Comms > Reporting
Test Route
MENU 5-4-2
00 - Log Events Only 0 1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
Comms > Reporting
System Route
MENU 5-4-3
00 - Log Events Only 0 1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
Comms > Reporting
Emergency Route
MENU 5-4-4
00 - Log Events Only 0 1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
Comms > Reporting >
Swinger Dialler
MENU 5-4-5
(*** System Wide Parameter ***) 0 6
Enter 0 – 15 + [OK] to program number of times the dialler
can report before lockout. 0 = Unlimited.
Comms > Reporting >
Burg Report Delay
MENU 5-4-6
(*** System Wide Parameter ***) 0 0 0
Seconds
Enter 0 – 255 seconds + [OK] to program the delay time in
seconds before reports are sent. 0 = No Delay.
Comms > Reporting >
Fire Report Delay
MENU 5-4-7
(*** System Wide Parameter ***) 0 0 0
Seconds
Enter 0 – 255 seconds + [OK] to program the delay time in
seconds before reports are sent. 0 = No Delay.
Comms > MyAlarm >
IP Address
MENU 5-5-0
Dest Nº 1
1
Digits
12
0 0 0 0 0 0 0 0 0 0 0 0
Factory Set. Do not change unless advised to do so by the
manufacturer.
Comms > MyAlarm >
IP Port
MENU 5-5-1
0 9 0 5 0
Factory Set. Do not change unless advised to do so by the
manufacturer.
Comms > MyAlarm >
MyAlarm Options
MENU 5-5-2
1 Disp Eth/WiFi Poll Fail N
2 Rpt Eth/WiFi Poll Fail N
3 Disp Cellular Poll Fail N
4 Rpt Cellular Poll Fail N
5 Disable Eth/WiFi MyAlar N
6 Reserved N
7 Reserved N
8 Static IP N

Table of Contents