25
Bosch Security Systems 10/22 BLCC615R
Solution 6000-IP
Quick Start Guide
Program Locations
The following section lists all of the programming locations
available in the Solution 6000-IP. The default values for
each parameter are shown in grey.
In order to keep the size of this guide down to a minimum
we have shown only one example for some parameters
and then listed the default values for the other similar
parameters. For example the user default table below
shows the default values for users 1 to 990. Similar tables
are used to show zone defaults etc.
Access Programming
Access > Commands >
Erase User
MENU 1-0-0
Access > PIN Codes >
Change Own PIN
MENU 1-1-0
Change Other PIN
MENU 1-1-1
Add PIN
MENU 1-1-2
Delete PIN
MENU 1-1-3
View PIN
MENU 1-1-4
Access > Token >
Add Token
MENU 1-2-0
Delete Token
MENU 1-2-1
Token Status
MENU 1-2-2
Edit Token
MENU 1-2-3
User Default Table
Parameter User 1 User 2 - 990
User PIN 2580
Name User 1 Name User 2 - 990
Area Assignment 1 1
User Options
Master User Y
Reserved
Arm Only
Can Bypass Y Y
Auto Bypass Y Y
Always Report Op/Cl Y Y
Reserved
Log Credential
TimeZone 01 01
Door Assignment
Table 15: User Default Programming Options
Access > RF Keyfob >
Add Keyfob
MENU 1-3-0
Delete Keyfob
MENU 1-3-1
Test Keyfob
MENU 1-3-2
Access > User Properties >
User Name
MENU 1-4-0
U s e r 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Access > User Properties >
Area Assignment
MENU 1-4-1
1 Security System Y
2 Area 2 Name N
3 Area 3 Name N
4 Area 4 Name N
5 Area 5 Name N
6 Area 6 Name N
7 Area 7 Name N
8 Area 8 Name N
Use the [] and [] keys to scroll the list of options. Select
the option required, then press [ON] or [OFF] to enable or
disable. A [] will display to indicate option set. Press [OK]
to save when finished.
Access > User Properties >
User Options
MENU 1-4-2
1 Master User Y
2 Reserved N
3 Arm Only N
4 Can Bypass Y
5 Auto Bypass Allowed Y
6 Always Report Op/Cl Y
7 Reserved N
8 Log Credential N