Solution 6000-IP
26
Bosch Security Systems 10/22 BLCC615R
Quick Start Guide
Access > User Properties >
TimeZone Access
MENU 1-4-4
0 1
00 - Disabled
01 - 24 Hour TimeZone 09 - TimeZone 9 Name
02 - TimeZone 2 Name 10 - TimeZone 10 Name
03 - TimeZone 3 Name 11 - TimeZone 11 Name
04 - TimeZone 4 Name 12 - TimeZone 12 Name
05 - TimeZone 5 Name 13 - TimeZone 13 Name
06 - TimeZone 6 Name 14 - TimeZone 14 Name
07 - TimeZone 7 Name 15 - TimeZone 15 Name
08 - TimeZone 8 Name 16 - TimeZone 16 Name
Enter 0 - 16 + [OK] to assign the user to a TimeZone – Can
only be assigned to one TimeZone.
i
Note
All users are assigned to TimeZone 1 by default.
This means they have 24 hour access to the system.
To restrict access. To restrict access to users, refer
to TimeZones.
Access > User Properties >
Door Assignment
MENU 1-4-5
1 Door 1 Name N
2 Door 2 Name N
3 Door 3 Name N
4 Door 4 Name N
5 Door 5 Name N
6 Door 6 Name N
7 Door 7 Name N
8 Door 8 Name N
9 Door 9 Name N
10 Door 10 Name N
11 Door 11 Name N
12 Door 12 Name N
13 Door 13 Name N
14 Door 14 Name N
15 Door 15 Name N
16 Door 16 Name N
Multiple doors can be assigned to each user. Press 1 – 16,
then press [ON] or [OFF] to toggle door on/off, then press
[OK] to save.
Access > User Properties >
User Expire Date
MENU 1-4-6
Access > Global Properties >
PIN Length
MENU 1-5-0
(*** System Wide Parameter ***) 0 4
00 - Variable 03 - 3 Digits 06 - 6 Digits
01 - 1 Digit 04 - 4 Digits 07 - 7 Digits
02 - 2 Digits 05 - 5 Digits 08 - 8 Digits
Enter 00 - 08 + [OK] to program the PIN length.
Access > Global Properties >
PIN Retry Count
MENU 1-5-1
(*** System Wide Parameter ***) 0 6
Use [] and [] keys or enter 00 – 15 + [OK] to program the
PIN retry count (00 = Unlimited).
Access > Global Properties >
Installer PIN
MENU 1-5-2
1 2 3 4 A A A A
(*** System Wide Parameter ***)
Use [0] – [9] keys to program the installer PIN + [OK] to
save. Installer PIN can be up to 8 digits long.
Access > Reporting
Access Route
MENU 1-6-0
00 - Log Events Only 0 0
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
Access > Reporting >
Access Options
MENU 1-6-1
1 Access Granted Y
2 Access Denied Y
3 Egress Granted Y
4 Egress Denied Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N

Table of Contents