29
Bosch Security Systems 10/22 BLCC615R
Solution 6000-IP
Quick Start Guide
Areas > Timers >
Auto Arm Pre Alert
MENU 2-8-4
(*** System Wide Parameter ***) 0 1 0
Minutes
Enter 000 – 255 + [OK] to program the pre-alert time in
minutes (0 = No Pre-Alert).
Areas > Timers >
Senior Watch Time
MENU 2-8-6
(*** System Wide Parameter ***) 0 0 0
Hours
Enter 000 – 255 + [OK] to program the senior watch
interval in hours.
Areas > Area Testing >
Area Watch
MENU 2-9-0
(*** System Wide Parameter ***) 0 1 2
Weeks
Enter 000 – 255 + [OK] to program the number of weeks
before registering an inactivity event.
Areas > Area Testing >
User Test Interval
MENU 2-9-1
(*** System Wide Parameter ***) 0 0 0
Days
Enter 000 – 255 + [OK] to program the number of days
before a user test is requested.
Areas > Area Testing >
Service Interval
MENU 2-9-2
(*** System Wide Parameter ***) 0 0 0
Weeks
Enter 000 – 255 + [OK] to program the number of weeks
required between installer services.
Areas > Area Testing >
Test Options
MENU 2-9-3
1 User Test Required Y
2 Reserved N
3 Reserved N
4 Reserved N
5 Reserved N
6 Walk Test Report Y
7 Walk Test 24Hr N
8 Walk Test Fire N
Input Programming
Inputs > Commands >
Zone Status
MENU 3-0-0
Zone Array
MENU 3-0-1
Bypass Zones
MENU 3-0-2
Set Chime Zones
MENU 3-0-3
Set Part 2 Zones
MENU 3-0-4
Smoke Sensor Reset
MENU 3-0-5
Inputs > Zone Properties >
Zone Name
MENU 3-1-0
Z o n e 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Inputs > Zone Properties >
Zone Type
MENU 3-1-1
0 1
00 - Not Used 08 - Hold Up 24Hr
01 - Burglary Delay 1 09 - Medical 24Hr
02 - Burglary Delay 2 10 - Panic 24Hr
03 - Burglary Instant 11 - Fire 24Hr
04 - Burg Inst No Exit 12 - Not Used
05 - Burg Handover 13 - Keyswitch Zone
06 - Burglary 24Hr 14 - Display Only
07 - Tamper 24Hr 15 - Non Burglary 24Hr
Use [] and [] keys or enter 0 – 15 + [OK] to program the
zone type.
Inputs > Zone Properties >
Area Assignment
MENU 3-1-2
0 1
00 - No Area
01 - Security System 05 - Area 5 Name
02 - Area 2 Name 06 - Area 6 Name
03 - Area 3 Name 07 - Area 7 Name
04 - Area 4 Name 08 - Area 8 Name
Use [] and [] keys or enter 0 - 8 then press [OK] to
program.